Evaluation of the Accuracy of Working Length Determination Using Cone-Beam Computed Tomography, Digital Periapical Radiography and Electronic Apex Locator: An In-vitro Study

  • تمام الراس احمد جامعة حماة
  • حسان الحلبية
الكلمات المفتاحية: working length, digital radiographies, electronic apex locator, CBCT

الملخص

Introduction: The purpose of this in-vitro study was to compare the accuracy of working length (WL) determination using three demotions (3D) cone-beam computed tomography (CBCT), 2-demotions digital periapical radiographies (2D) and electronic apex locator (EAL). Methods and Materials: A total of 40 human extracted single-rooted teeth were chosen. Access cavity was performed, and actual root canal lengths were measured. Then, a file was advanced into the canal until the WL was detected by digital radiography. Subsequently, the WL was measured using EAL, and CBCT. These three measurements were compared and the data were analyzed using the T-student test. The level of significance was set at 0.05. Results: The mean values for WL determination differences using electronic apex locator, periapical radiograph and CBCT images were not statistically significant (P>0.05). Conclusion: The accuracy of working length determination using 3D images was equal to electronic apex locator and digital radiographic at least with two different angels.

References

1. الحلبية، حسان. (2018). "مداواة الأسنان اللبية"، جامعة حماه، سوريا، حماة.
2. AAE 2016. Glossary of Endodontic Terms.
3. Amin, Janki, et al. "Comparison of accuracy and reliability of working length determination using cone beam computed tomography and electronic apex locator: a systematic review." Journal of Contemporary Dental Practice 20 (2019): 1118-1123.‏
4. Connert T, Hülber-J M, Godt A, Löst C, ElAyouti A. Accuracy of endodontic working length determination using cone beam computed tomography. Int Endod J 2014; 47:698-703.
5. Custer C. Exact methods for locating the apical foramen, J Natl Dent Assoc 1918.
6. D’Assunção FL, de Albuquerque DS, de Queiroz Ferreira LC. The ability of two apex locators to locate the apical foramen: an in vitro study. J Endod 2006; 32: 560-2
7. ElAyouti A, Weiger R, Löst. The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length. C. J Endod. 2002;28:116–119.
8. Fayad MI, Nair M, Levin MD, Benavides E, Rubinstein RA, Barghan S, Hirschberg CS, Ruprecht A. AAE and AAOMR joint position statement: use of cone beam computed tomography in endodontics 2015 update. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(4):508–12.
9. Faraj, Bestoon Mohammed. "Root canal curvature as a prognostic factor influencing the diagnostic accuracy of radiographic working length determination and postoperative canal axis modification: an in vitro comparative study." BMC Oral Health 21 (2021): 1-9.‏
10. Gambarini G, Ropini P, Piasecki L, Costantini R, Carneiro E, Testarelli L, Dummer PMH. A preliminary assessment of a new dedicated endodontic software for use with CBCT images to evaluate the canal complexity of mandibular molars. Int Endod J. 2018;51(3):259–68.
11. Gurel MA, Helvacioglu Kivanc B, Ekici A. A comparative assessment of the accuracies of Raypex 5, Raypex 6, iPex and iPex II electronic apex locators: An in vitro study. J Istanb Univ Fac Dent. 2017 Jan 2;51(1):28-33. doi: 10.17096/jiufd.61309. PMID: 28955583; PMCID: PMC5573492.
12. Grossman, L.: Endodontics practice.10th ed.,lea&feibiger. 1981; (193-195), (178- 179), (212-213), 216.
13. Hasselgren G. Where shall the root filling end? NY St Dent J 1994; 60: 6.
14. Jeger FB, Janner SF, Bornstein MM, Lussi A. Endodontic working length measurement with preexisting cone-beam computed tomography scanning: A prospective, controlled clinical study. J Endod 2012; 38:884-8.
15. Kustarci A, Arslan D, Er K, Kocak S, Altunbas D. Comparison of various current electronic apex locators to determine the working length using the clearing technique. Niger J Clin Pract. 2015;18:359.
16. Khan SA, Khanna R, Navit S, Jabeen S, Grover N, Pramanik S. Comparison of Radiovisiography, an Apex Locator and an Integrated Endomotor-inbuilt Apex Locator in Primary Teeth Endometrics. Int J Clin Pediatr Dent. 2022;15(Suppl 1):S18-S21. doi: 10.5005/jp-journals-10005-2123. PMID: 35645506; PMCID: PMC9108817.
17. MAREK, E.;LAGOSKA,R.; KOT, K.; WOZNNIAK, K.; LIPSKI, M.The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators.BMS Oral Health, v .20,n 3 ,p. 1-8, 2020
18. Melius B, Jiang J, Zhu Q. Measurement of the distance between the minor foramen and the anatomic apex by digital and conventional radiography. J Endod 2002; 28: 125-6
19. Martins JNR, Marques D, Mata A, Caramês J. Clinical efficacy of electronic apex locators: systematic review. J Endod. 2014;40(6):759–77.
20. Nasiri K, Wrbas KT. Accuracy of different generations of apex locators in determining working length; a systematic review and meta-analysis Saudi Dent J. 2022;34:11–20.
21. Osei-Bonsu F, Ampofo PC, Nyako EA, Hewlett SA, Buckman VA, Konadu AB, Blankson PK, Ndanu T. Accuracy of the electronic apex locator, tactile, and radiographic methods in working length determination. J Conserv Dent. 2023 May-Jun;26(3):311-315. doi: 10.4103/jcd.jcd_45_23. Epub 2023 May 16. PMID: 37398858; PMCID: PMC10309118.
22. Pietrzycka, Krystyna, Mateusz Radwański, and Halina Pawlicka. "Evaluation of working length determination based on the analysis of cone-beam computed tomographic images and an electronic apex locator: a retrospective study." Pomeranian Journal of Life Sciences 66.4 (2020): 9-13.‏
23. Suzuki K. Experimental study on iontophoresis.Journal of the Japanese stomatologicalsoviety.1942;16:p.411.
24. Üstün, Yakup, et al. "Evaluation of the reliability of cone-beam computed tomography scanning and electronic apex locator measurements in working length determination of teeth with large periapical lesions." Journal of endodontics 42.9 (2016): 1334-1337.‏
25. Van Pham, Khoa. "Endodontic length measurements using 3D Endo, cone-beam computed tomography, and electronic apex locator." BMC Oral Health 21.1 (2021): 1-7.‏
26. Woolhiser GA, Brand JW, Hoen MM, Geist JR, Pikula AA, Pink FE. Accuracy of film-based, digital, and enhances digital images for endodontic length determination. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005; 99: 499-504.
منشور
2024-10-10
How to Cite
احمدت. ا., & الحلبيةح. (2024). Evaluation of the Accuracy of Working Length Determination Using Cone-Beam Computed Tomography, Digital Periapical Radiography and Electronic Apex Locator: An In-vitro Study. Journal of Hama University , 7(السابع). Retrieved from https://hama-univ.edu.sy/ojs/index.php/huj/article/view/1883